BW Technologies gas detector calibration gases and accessories

'Bump testing' and routine calibration of safety gas detectors is essential to ensure correct operation.

'Bump Testing' - Performance check
BW recommends to 'bump test' the sensors fitted to safety gas detectors before each day's use to confirm their ability to respond to gas by exposing the detector to a gas concentration that exceeds the alarm setpoints, manually verify that the audible and visual alarms are activated and to calibrate the detector if the readings are not within the specified limits.

Calibration
Gas detectors must be calibrated on a regular schedule, depending on use and sensor exposure to poisons and contaminants. BW recommends calibrating at least once every 180 days (6 months). The combustible gas sensor must be checked with a known concentration of calibration gas after any known exposure to catalyst contaminants/poisons (sulfur compounds, silicon vapors, halogenated compounds, etc).

Calibration accessories
A range of calibration gases and accessories is available to simplify 'bump testing' and calibration so that you can have confidence that your BW technologies gas detectors are in perfect working order.

Warning:
Always read and understand the gas detector user manual completely before operating or servicing.
Buy BW calibration accessories online now, just click on thebuy onlinenext to the product price to add it to your shopping basket.
3517-001 BW test gas (34L) 2.2% CH4 (50% LEL EN61779)/18.0% O2/25 ppm H2S/100 ppm CO - CG-Q34-5 £83.00
3517-101 BW test gas (58L) 2.2% CH4 (50% LEL EN61779)/18.0% O2/25 ppm H2S/100 ppm CO - CG-Q58-5 £120.00
3517-002 BW test gas (34L) 2.2% CH4 (50% LEL methane EN61779)/air - CG2-J-2.2-34 £80.00
3517-003 BW test gas (34L) 2.2% CH4 (50% LEL methane EN61779)/18.0% oxygen (O2) - CG2-JX-2.2-34 £70.00
3517-103 BW test gas (58L) 2.2% CH4 (50% LEL methane EN61779)/18.0% oxygen (O2) - CG2-JX-2.2-58 £80.00
3517-004 BW test gas (34L) 25ppm hydrogen sulphide (H2S)/balance N2 - CG2-H-25-34 £75.00
3517-104 BW test gas (58L) 25ppm Hydrogen sulphide (H2S)/balance N2 - G0042-H25 £80.00
3517-005 BW test gas (34L) 10ppm hydrogen cyanide (HCN)/balance N2 - CG2-Z-10-34 £150.00
3517-105 BW test gas (58L) 10ppm hydrogen cyanide (HCN)/balance N2 - CG2-Z-10-58 £200.00
3517-006 BW test gas (34L) 50ppm ammonia (NH3)/balance air - CG2-A-50-34 £150.00
3517-106 BW test gas (58L) 50ppm ammonia (NH3)/balance N2 - CG2-A-50-58 £200.00
3517-107 BW test gas (58L) 100ppm carbon monoxide (CO)/balance N2 - CG2-M-100-58 £95.00
3517-008 BW test gas (34L) 10ppm nitrogen dioxide (NO2)/balance air - CG2-D-10-34 £150.00
3517-108 BW test gas (58L) 10ppm nitrogen dioxide (NO2)/balance air - CG2-D-10-58 £200.00
3517-009 BW test gas (34L) 20ppm sulphur dioxide (SO2)/balance N2 - CG2-S-20-34 £80.00
3517-109 BW test gas (58L) 20ppm sulphur dioxide (SO2)/balance N2 - CG2-S-20-58 £90.00
3517-010 BW test gas (34L) 50ppm nitric oxide (NO)/balance N2 - CG2-N-50-34 £150.00
3517-011 BW test gas (34L) 100ppm isobutylene (C4H8)/balance air - CG2-IB-100-34AL £70.00
3517-111 BW test gas (58L) 100ppm isobutylene (C4H8)/balance air - CG2-IB-100-58AL £80.00
3516-001 BW calibration gas regulator (0.5LPM) REG-0.5 (for manual calibration) £85.00
3516-002 BW demand flow gas regulator REG-DF-1 (for automated calibration using BW MicroDock II) £200.00
3580-001 BW Technologies GasAlertMicroClip/XT replacement test cap and hose MC-TC-1 £8.00
3580-002 BW Technologies GasAlertQuattro replacement test cap and hose QT-TC-1 £6.00
3580-003 BW Technologies GasAlertMicro 5 replacement test cap and hose M5-TC-1 £6.00
3580-004 BW Technologies GasAlert Extreme replacement test cap and hose GA-TC-1 £6.00